Experiment: Ng Research Group_20120524_ISOPRENE/hydrogen peroxide_Hydroxyl radical_No Seed_dry
Experiment
Name: Ng Research Group_20120524_ISOPRENE/hydrogen peroxide_Hydroxyl radical_No Seed_dry
Date: 2012-05-24
Organization
Ng Research Group
Chamber
PNNL Chamber
Experiment Set
isoprene_OH_Xu
Goals
Measure the volatility of isoprene + OH SOA under different NOx level
Summary
See Xu et al. 2014 EST for findings.Experiment Details
Categories:
- Gas phase chemical reaction
- Volatility and partitioning
- Aerosol formation
Relative Humidity: 5
Seeded Experiment: No
Fuchs Adjusted Surface Area:
Condensation sink rate coefficient: 5
Reaction type:
Oxidant Name: Hydroxyl radical
Initial Oxidant Concentration Value: 0.82e6 (molecules_per_cubic_centimeter)
RO2 Main Fate: HO2
RO2 Lifetime: (Seconds)
Pressure:
Data Set plots
Experiment Set Details
Name: isoprene_OH_Xu
Time format and units:
Description:
isoprene + OH SOA volatility
Collaborators:
Contacts
Principal investigator:
Nga (Sally) Lee Ng
E-mail: ng@chbe.gatech.edu
OrcID: 0000-0001-8460-4765
Data Manager:
Taekyu Joo
Phone: (404) 385-2149
E-mail: tjoo6@gatech.edu
Expt2_20120524_TimeLine.csv
Timeline
Time (Local time) | Action |
5/24/2012 10:59 | inject 3.3uL isoprene |
5/24/2012 11:56 | inject 2uL isoprene |
5/24/2012 12:05 | inject 50uL H2O2 |
5/24/2012 12:45 | light on |
5/25/2012 9:35 | light off |
Citations
Characterizations
(None)
Particle Loss Characterizations:
(None)
Vapor Loss Characterizations:
(None)
Chamber Details
Name: PNNL Chamber
Volume in cubic meters: 10.6
Shape: Rectangular Prism
Surface area in cubic meters: 28
Flow Mode: Batch
Flow through rate in liters per minute:
Body Material: Teflon
Body thickness: 2
Replacement date:
Replacement frequency: Annually
Cleaning method:
Flushing with air
Flushing with air with UV lights on
Oxidation
Temperature
o3 background: < 1
nox background: < 1
Particle background in micrograms per cubic meter: < 1
Air filtration method: AADCO pure air generator
Mixing method: 0
Mixing method material: Convective turbulence
Temparature Control: Yes
Temparature measurements recorded: Yes
Temparature range (min degrees celcius): 15
Temparature range (max degrees celcius): 45
Humidity Control: Yes
Humidity Measurements Recorded: Yes
Relative humidity range (min percent): 0
Relative humidity range (max percent): 85
Particle experiment capability: 1
Lights: Yes
Light source type(s):
Black Light
Supplemental information:
Additional Notes: