Experiment: NCAR_20170705_nitric oxide/hydrogen peroxide_Hydroxyl radical_No Seed_CSTR_blank_170705
Experiment
Name: NCAR_20170705_nitric oxide/hydrogen peroxide_Hydroxyl radical_No Seed_CSTR_blank_170705
Date: 2017-07-05
Organization
NCAR
Chamber
NCAR 3rd Floor Teflon
Experiment Set
'Intermediate-NO' regime experiments
Goals
Probing the steady state NO and O3 concentration that could be reached by varying the concentrations of reactants H2O2 and NO in the photooxidation experiment
Summary
First, a given amount of H2O2 and NO is continuously injected into the chamber till the steady state is established. Second, the UV lights are on to initiate photochemistry till another steady state is established.Experiment Details
Categories:
- Gas phase chemical reaction
- Blank/Control
Relative Humidity: 10
Seeded Experiment: No
Fuchs Adjusted Surface Area:
Condensation sink rate coefficient: 10
Reaction type:
Oxidant Name: Hydroxyl radical
Initial Oxidant Concentration Value: 0 (molecules_per_cubic_centimeter)
RO2 Main Fate: No RO2 chemistry
RO2 Lifetime: (Seconds)
Pressure: 0.8 atm
Data Sets
ID | Instrument | File | |
---|---|---|---|
133 | O3 monitor |
O3_170705.csv
|
|
134 | NO monitor |
NO_170705.csv
|
Data Set plots
Experiment Set Details
Name: 'Intermediate-NO' regime experiments
Time format and units:
Description:
We performed a series of experiments running at continuous flow steady state mode, focusing on establishing an ‘intermediate NO’ regime characterized by a constant steady-state NO level ranging from tens of ppt to a few ppb in the chamber
Collaborators:
Contacts
Principal investigator:
John Orlando
Phone: 303 497 1486
E-mail: orlando@ucar.edu
Data Manager:
Geoff Tyndall
Phone: 303 497 1472
E-mail: tyndall@ucar.edu
Timeline_CSTR_blank_170705.csv
Timeline
Time_UTC | Event Description |
17:30 | started DOS injection , 30 minute injection = 150 ug/m3 |
18:18 | injected VOC (50 ul C6, 40 ul C8, 25 uL C9, 18 uL C10) (fan on 1 min) |
18:24 | injected 26 Torr (2 L bulb) NO, Fan on 1 min |
18:30 | Injected 27 Torr MeNO2 ,Fan on 1 min |
18:34 | started UV cycle |
20:06 | started flush cycle to clean bag (experiment end) |
Citations
Characterizations
2016-02-18 (#23)
Particle Loss Characterizations:
(None)
Vapor Loss Characterizations:
(None)
Chamber Details
Name: NCAR 3rd Floor Teflon
Volume in cubic meters: 10
Shape: Rectangular Prism
Surface area in cubic meters: 27.85
Flow Mode: CSTR
Flow through rate in liters per minute: 40
Body Material: Teflon
Body thickness: 5
Replacement date: 2017-01-17
Replacement frequency: As needed
Cleaning method:
Flushing with air
Flushing with air with UV lights on
o3 background: 0
nox background: 0.025
Particle background in micrograms per cubic meter: 0.1
Air filtration method: Model 737, Aadco Instruments, OH
Mixing method: 0
Mixing method material:
Temparature Control: No
Temparature measurements recorded: Yes
Temparature range (min degrees celcius): 22
Temparature range (max degrees celcius): 35
Humidity Control: Yes
Humidity Measurements Recorded: Yes
Relative humidity range (min percent): 3
Relative humidity range (max percent): 85
Particle experiment capability: 1
Lights: Yes
Light source type(s):
UVA Black Lamps
Supplemental information:
Additional Notes: