Experiment: Caltech Atmospheric Chamber_20210301_DECAMETHYLCYCLOPENTASILOXANE_Hydroxyl radical_No Seed_F16toF19
Experiment
Name: Caltech Atmospheric Chamber_20210301_DECAMETHYLCYCLOPENTASILOXANE_Hydroxyl radical_No Seed_F16toF19
Date: 2021-03-01
Organization
Caltech Atmospheric Chamber
Chamber
CPOT
Experiment Set
D5 CPOT Experiments
Goals
Measure SOA yield of D5
Summary
This is the set of experiments performed with D5 where the RH was adjusted so that O3 made variable OH concentrations. This is half of the set (see 210203 for more). These are experiments F16 through F19.Experiment Details
Categories:
- Aerosol formation
Relative Humidity: 00
Seeded Experiment: No
Fuchs Adjusted Surface Area:
Condensation sink rate coefficient: 00
Reaction type:
Oxidant Name: Hydroxyl radical
Initial Oxidant Concentration Value: variable (e7 to e9) (molecules_per_cubic_centimeter)
RO2 Main Fate: HO2
RO2 Lifetime: (Seconds)
Pressure:
Data Sets
ID | Instrument | File | |
---|---|---|---|
3616 | XMAN SMPS |
210301_FB_SMPS_Complete.csv
|
|
3617 | RHT Probe |
210301_FB_RHT_REAL.csv
|
|
3618 | CIMS |
210301_FB_CIMS.csv
|
|
3619 | GC - FID |
210301_FB_GC.csv
|
|
3620 | NOxTele |
210301_FB_NOx_O3.csv
|
Data Set plots
Experiment Set Details
Name: D5 CPOT Experiments
Time format and units:
Description:
Decamethylcyclopentasiloxane (D5, C10H30O5Si5) is measured at ppt levels outdoors and ppb levels indoors. Primarily used in personal care products, its outdoor concentration is correlated to population density. Since understanding the aerosol formation potential of volatile chemical products is critical to understanding particulate matter in urban areas, the secondary organic aerosol yield of D5 was studied under a wide range of OH concentrations and exposures using both batch-mode chamber and continuously run flow tube experiments. These results were comprehensively analyzed and compared to two other secondary organic aerosol (SOA) yield datasets from literature. It was found that the SOA yield from the oxidation of D5 is extremely dependent on the OH concentration or exposure.
Collaborators:
- Sophia M Charan Caltech
- Yuanlong Huang Caltech
Contacts
Principal investigator:
John H Seinfeld
Phone: (626) 395-4635
E-mail: seinfeld@caltech.edu
OrcID: https://orcid.org/0000-0003-1344-4068
Data Manager:
Stephanie Kong
Phone: 626-395-3194
E-mail: wkong@caltech.edu
Reactant
Reactant | Compound type | Concentration | Concentration units |
---|---|---|---|
DECAMETHYLCYCLOPENTASILOXANE (10913) |
210301_FB_TimeLine_FLOWSonoff.csv
Timeline
Time (America/Los_Angeles) | Action |
3/1/21 12:27 | Flow of 7, D5 syringe setting #1, flow on |
3/1/21 15:30 | Flow of 7, D5 syringe setting #1, flow off |
3/1/21 16:00 | Flow of 7, D5 syringe setting #1, background, flow on |
3/1/21 19:03 | Flow of 7, D5 syringe setting #1, background, flow off |
3/1/21 19:08 | Flow of 7, D5 syringe setting #2, background, flow on |
3/1/21 23:20 | Flow of 7, D5 syringe setting #2, background, flow off |
3/2/21 0:00 | Flow of 7, D5 syringe setting #2, flow on |
3/2/21 7:45 | Flow of 7, D5 syringe setting #2, flow off |
3/2/21 8:02 | Flow of 3, D5 syringe setting #2, flow on |
3/2/21 11:14 | Flow of 3, D5 syringe setting #2, flow off |
3/2/21 11:15 | Flow of 3, D5 syringe setting #1, flow on |
3/2/21 14:36 | Flow of 3, D5 syringe setting #1, flow off |
Citations
Characterizations
(None)
Particle Loss Characterizations:
(None)
Vapor Loss Characterizations:
(None)
Chamber Details
Name: CPOT
Volume in cubic meters: 0.043
Shape: Cylindrical
Surface area in cubic meters: 1.18
Flow Mode: Flow-through
Flow through rate in liters per minute: 2
Body Material: Glass/Quartz
Body thickness:
Replacement date:
Replacement frequency: As needed
Cleaning method:
Flushing with air
Flushing with air with UV lights on
Flushing with N2
Cleaning with solvent
o3 background:
nox background: 0.1
Particle background in micrograms per cubic meter: 0
Air filtration method: Custom Filter
Mixing method: 0
Mixing method material: Axial dispersion
Temparature Control: Yes
Temparature measurements recorded: Yes
Temparature range (min degrees celcius): 20
Temparature range (max degrees celcius): 45
Humidity Control: Yes
Humidity Measurements Recorded: Yes
Relative humidity range (min percent): 5
Relative humidity range (max percent): 100
Particle experiment capability: 1
Lights: Yes
Light source type(s):
UVA Black Lamps
Supplemental information: https://doi.org/10.5194/amt-10-839-2017
Additional Notes: