Experiment: UCR-CECERT-APL-Cocker Group_20180831_ALPHA-PINENE_Ozone_No Seed_EPA2384A - Chen Le
Experiment
Name: UCR-CECERT-APL-Cocker Group_20180831_ALPHA-PINENE_Ozone_No Seed_EPA2384A - Chen Le
Date: 2018-08-31
Organization
UCR-CECERT-APL-Cocker Group
Chamber
EPA chamber
Experiment Set
a-Pinene Ozonolysis with T&RH Swings 2018
Goals
How temperature and RH change as a whole affects the particle parameters.
Summary
How temperature and RH change as a whole affects the particle parameters.Experiment Details
Categories:
- Photolysis, any phase
- Aerosol formation
- Aerosol aging
Relative Humidity: 99.99
Seeded Experiment: No
Fuchs Adjusted Surface Area:
Condensation sink rate coefficient: 99.99
Reaction type:
Oxidant Name: Ozone
Initial Oxidant Concentration Value: 500 (parts_per_billion)
RO2 Main Fate: Not Sure
RO2 Lifetime: (Seconds)
Pressure: 0.015'' H2O
Data Sets
ID | Instrument | File | |
---|---|---|---|
2489 | SMPS |
EPA2384A_SMPS.csv
|
|
2490 | APM-SMPS |
EPA2384A_APM.csv
|
|
2491 | VTDMA |
EPA2384A_VTDMA.csv
|
|
2492 | Ozone Box |
EPA2384A_O3.csv
|
|
2493 | NOx Box |
EPA2384A_NOx.csv
|
|
2494 | SMPS - SizeD |
EPA2384A_SizeD.csv
|
|
2495 | TC |
EPA2384A_Temperature.csv
|
Data Set plots
Experiment Set Details
Name: a-Pinene Ozonolysis with T&RH Swings 2018
Time format and units: Time format in timeline is the absolute local time.
Description:
a-Pinene ozonolysis with temperature & humidity swings.
Collaborators:
- Chen Le APL
- Weihan Peng APL
- Huanhuan Jiang Env. Sci. Department
- Ying-Hsuan Lin Env. Sci. Department, PI
- Zixu Zhao Chemistry Department
- Qi Xu Chemistry Department
- Haofei Zhang Chemistry Department, PI
- David Cocker APL, PI
Contacts
Principal investigator:
David Cocker
E-mail: dcocker@engr.ucr.edu
Data Manager:
Chen Le
Phone: 9516603455
E-mail: cle030@ucr.edu
Reactant
Reactant | Compound type | Concentration | Concentration units |
---|---|---|---|
ALPHA-PINENE (319064711) |
|
250 | Parts Per Billion |
20180831_EPA2384_TimeLine.csv
Timeline
Time (America/Los_Angeles) | Action |
0:00 | Close valve 14; 60-degree turn fill air on humidifier overnight |
9:03 | NO span starts; flow 2|20|15|off |
9:19 | NO 70.4; NOx 73.0; GPT span starts; flow 2|20|15|0.7 |
9:24 | Licor dew point 2C @ room temp 25C; humid air off |
9:25 | Fill air off; Air Handlers on; Box temp 18C; Chiller #1 on (60-62-64F) |
9:28 | Inject CO @1000 ccm to W bag for 45 min |
9:29 | NO 46.7; NOx 72.5; O3 span starts; flow 2|20|off|0.7 |
10:05 | Inject 40uL PFB into W bag |
10:08 | Inject 132.5uL a-Pinene into W bag |
10:09 | O3 32.8; Starting E--W--Z sampling |
10:28 | Internally mix W bag for 1 min |
10:39 | Inject O3 @30 psi into W bag for 30 min |
11:10 | Elevators on (0.015'; 1s); PM formation T = 19.9C |
13:53 | Box 2C; Chiller #1 20-22-24F |
15:00 | Heaters on; Box 22C; Chiller #1 60-62-64F; Chiller #1 off |
15:55 | Chiller #1 on |
16:12 | Safety valve 120F; Box 38C; Chiller #1 90-92-94F; Chiller #1 off |
17:37 | Chiller #1 on |
17:57 | Heaters off; Box 18C; Chiller #1 45-47-49F |
19:02 | End of experiment (W:213 E:375) |
Citations
Characterizations
(None)
Particle Loss Characterizations:
(None)
Vapor Loss Characterizations:
(None)
Chamber Details
Name: EPA chamber
Volume in cubic meters: 84.2
Shape: Rectangular Prism
Surface area in cubic meters: 126
Flow Mode: Batch
Flow through rate in liters per minute:
Body Material: Teflon
Body thickness: 2
Replacement date: 2017-11-07
Replacement frequency: As needed
Cleaning method:
Flushing with air
Flushing with air with UV lights on
Oxidation
Wipe with ultra-pure water if needed
o3 background: 10
nox background: 0
Particle background in micrograms per cubic meter: 0
Air filtration method: The chamber is using zero air from our air purification system
Mixing method: 0
Mixing method material:
Temparature Control: Yes
Temparature measurements recorded: Yes
Temparature range (min degrees celcius): 5
Temparature range (max degrees celcius): 45
Humidity Control: Yes
Humidity Measurements Recorded: Yes
Relative humidity range (min percent): 0.01
Relative humidity range (max percent): 80
Particle experiment capability: 1
Lights: Yes
Light source type(s):
350nm UVA Black Lamps
Supplemental information:
Additional Notes: