Experiment: UCR-CECERT-APL-Cocker Group_20141204_MEMP/H2O2_Hydroxyl radical_No Seed_EPA2007B - Sara
Experiment
Name: UCR-CECERT-APL-Cocker Group_20141204_MEMP/H2O2_Hydroxyl radical_No Seed_EPA2007B - Sara
Date: 2014-12-04
Organization
UCR-CECERT-APL-Cocker Group
Chamber
EPA chamber
Experiment Set
Sara Li_Old test
Goals
Photo-oxidation of MEMP with OH under black lights.
Summary
Target: 1ppm H2O2+80 ppb EGDBE(A)/ MEMP(B) INSTRUMENTS: SMPS, GC1, AMS, APM, SYFTExperiment Details
Categories:
- Photolysis, any phase
- Aerosol formation
- Aerosol aging
Relative Humidity: 0.01
Seeded Experiment: No
Fuchs Adjusted Surface Area:
Condensation sink rate coefficient: 0.01
Reaction type:
Oxidant Name: Hydroxyl radical
Initial Oxidant Concentration Value: N/A (molecules_per_cubic_centimeter)
RO2 Main Fate: HO2
RO2 Lifetime: (Seconds)
Pressure: 0.015'' H2O
Data Sets
ID | Instrument | File | |
---|---|---|---|
3002 | SMPS |
EPA2007B_SMPS.csv
|
|
3003 | SMPS - SizeD |
EPA2007B_SizeD.csv
|
|
3004 | Ozone Box |
EPA2007B_O3.csv
|
|
3005 | NOx Box |
EPA2007B_NOx.csv
|
|
3006 | TC |
EPA2007B_Temperature.csv
|
Data Set plots
Experiment Set Details
Name: Sara Li_Old test
Time format and units:
Description:
To investigate the SOA yield from DEGEE in low NOx condition.
Collaborators:
Contacts
Principal investigator:
David Cocker
E-mail: dcocker@engr.ucr.edu
Data Manager:
Chen Le
Phone: 9516603455
E-mail: cle030@ucr.edu
Reactants
Reactant | Compound type | Concentration | Concentration units |
---|---|---|---|
MEMP | 80 | Parts Per Billion | |
H2O2 | 1 | Parts Per Million |
20141204_EPA2007_TimeLine.csv
Timeline
File not found... |
Citations
Characterizations
(None)
Particle Loss Characterizations:
(None)
Vapor Loss Characterizations:
(None)
Chamber Details
Name: EPA chamber
Volume in cubic meters: 84.2
Shape: Rectangular Prism
Surface area in cubic meters: 126
Flow Mode: Batch
Flow through rate in liters per minute:
Body Material: Teflon
Body thickness: 2
Replacement date: 2017-11-07
Replacement frequency: As needed
Cleaning method:
Flushing with air
Flushing with air with UV lights on
Oxidation
Wipe with ultra-pure water if needed
o3 background: 10
nox background: 0
Particle background in micrograms per cubic meter: 0
Air filtration method: The chamber is using zero air from our air purification system
Mixing method: 0
Mixing method material:
Temparature Control: Yes
Temparature measurements recorded: Yes
Temparature range (min degrees celcius): 5
Temparature range (max degrees celcius): 45
Humidity Control: Yes
Humidity Measurements Recorded: Yes
Relative humidity range (min percent): 0.01
Relative humidity range (max percent): 80
Particle experiment capability: 1
Lights: Yes
Light source type(s):
350nm UVA Black Lamps
Supplemental information:
Additional Notes: