Experiment: UCR-CECERT-APL-Cocker Group_20150202_2-METHYLNAPHTHALENE/H2O2/M-XYLENE_Hydroxyl radical_No Seed_EPA2018A - Candice
Experiment
Name: UCR-CECERT-APL-Cocker Group_20150202_2-METHYLNAPHTHALENE/H2O2/M-XYLENE_Hydroxyl radical_No Seed_EPA2018A - Candice
Date: 2015-02-02
Organization
UCR-CECERT-APL-Cocker Group
Chamber
EPA chamber
Experiment Set
Sara Li_Old test
Goals
Photo-oxidation of two VOCs with OH under black lights.
Summary
Target: 2-methylnaphthalene 30 ppb+H2O2 1 ppm (both) +m-xylene 90 ppb(A) INSTRUMENTS: SMPS, GC1, AMS, APM, SYFTExperiment Details
Categories:
- Photolysis, any phase
- Aerosol formation
- Aerosol aging
Relative Humidity: 0.01
Seeded Experiment: No
Fuchs Adjusted Surface Area:
Condensation sink rate coefficient: 0.01
Reaction type:
Oxidant Name: Hydroxyl radical
Initial Oxidant Concentration Value: N/A (molecules_per_cubic_centimeter)
RO2 Main Fate: Not Sure
RO2 Lifetime: (Seconds)
Pressure: 0.015'' H2O
Data Sets
ID | Instrument | File | |
---|---|---|---|
3080 | SMPS |
EPA2018A_SMPS.csv
|
|
3081 | APM-SMPS |
EPA2018A_APM.csv
|
|
3082 | Ozone Box |
EPA2018A_O3.csv
|
|
3083 | NOx Box |
EPA2018A_NOx.csv
|
|
3084 | SMPS - SizeD |
EPA2018A_SizeD.csv
|
|
3085 | TC |
EPA2018A_Temperature.csv
|
|
3086 | Licor |
EPA2018A_Licor.csv
|
Data Set plots
Experiment Set Details
Name: Sara Li_Old test
Time format and units:
Description:
To investigate the SOA yield from DEGEE in low NOx condition.
Collaborators:
Contacts
Principal investigator:
David Cocker
E-mail: dcocker@engr.ucr.edu
Data Manager:
Chen Le
Phone: 9516603455
E-mail: cle030@ucr.edu
20150202_EPA2018_TimeLine.csv
Timeline
Time (America/Los_Angeles) | Action |
07:39 | NO span starts; flow 2|20|35|off |
07:55 | NO 89.89; NOx 89.36; CO 15.19; GPT span starts; flow 2|20|35|0.7 |
08:11 | NO 61.04; NOx 87.40; CO 15.19; O3 span starts; flow 2|20|off|0.7 |
08:20 | Fill air off; Air Handlers on; Heaters on; Chiller #1 on |
08:24 | Inject 100 uL PFH into both bags |
08:34 | Inject 31.7 mg 2-methylnaphthalene into both bags @ 60 *C; 10 lpm |
08:39 | O3 34.67; Starting E--W--Z sampling |
09:00 | Inject 400 uL H2O2 into both bags @ 69 *C; 10 lpm |
09:19 | Mix bags E-W for 10 mins |
09:34 | Close valve 14 |
09:38 | Inject 36 uL m-xylene into W bag |
09:48 | Mix W bag internally for 1 min |
09:58 | BL on; heater off |
18:09 | BL off; air handlers off; W 26; E 262 |
Citations
Characterizations
(None)
Particle Loss Characterizations:
(None)
Vapor Loss Characterizations:
(None)
Chamber Details
Name: EPA chamber
Volume in cubic meters: 84.2
Shape: Rectangular Prism
Surface area in cubic meters: 126
Flow Mode: Batch
Flow through rate in liters per minute:
Body Material: Teflon
Body thickness: 2
Replacement date: 2017-11-07
Replacement frequency: As needed
Cleaning method:
Flushing with air
Flushing with air with UV lights on
Oxidation
Wipe with ultra-pure water if needed
o3 background: 10
nox background: 0
Particle background in micrograms per cubic meter: 0
Air filtration method: The chamber is using zero air from our air purification system
Mixing method: 0
Mixing method material:
Temparature Control: Yes
Temparature measurements recorded: Yes
Temparature range (min degrees celcius): 5
Temparature range (max degrees celcius): 45
Humidity Control: Yes
Humidity Measurements Recorded: Yes
Relative humidity range (min percent): 0.01
Relative humidity range (max percent): 80
Particle experiment capability: 1
Lights: Yes
Light source type(s):
350nm UVA Black Lamps
Supplemental information:
Additional Notes: