Experiment: UCR-CECERT-APL-Cocker Group_20110415_ISOPRENE/H2O2/NOx_Hydroxyl radical_No Seed_EPA1411B - Chris
Experiment
Name: UCR-CECERT-APL-Cocker Group_20110415_ISOPRENE/H2O2/NOx_Hydroxyl radical_No Seed_EPA1411B - Chris
Date: 2011-04-15
Organization
UCR-CECERT-APL-Cocker Group
Chamber
EPA chamber
Experiment Set
Sara Li_Old test
Goals
Photo-oxidation of isoprene with OH with the existence of NOx under black lights
Summary
Targets: isoprene 0.250 ppm both NOx 0.250 ppm both H2O2 3 ppm West 1.5 ppm East INSTRUMENTS: PILS-ToF (- ionization), GC, SMPS, vTDMA, APM, AMSExperiment Details
Categories:
- Photolysis, any phase
- Aerosol formation
- Aerosol aging
- Blank/Control
Relative Humidity: 0.01
Seeded Experiment: No
Fuchs Adjusted Surface Area:
Condensation sink rate coefficient: 0.01
Reaction type:
Oxidant Name: Hydroxyl radical
Initial Oxidant Concentration Value: N/A (molecules_per_cubic_centimeter)
RO2 Main Fate: HO2
RO2 Lifetime: (Seconds)
Pressure: 0.015'' H2O
Data Sets
ID | Instrument | File | |
---|---|---|---|
3162 | SMPS |
EPA1411B_SMPS.csv
|
|
3163 | Ozone Box |
EPA1411B_O3.csv
|
|
3164 | NOx Box |
EPA1411B_NOx.csv
|
|
3165 | SMPS - SizeD |
EPA1411B_SizeD.csv
|
|
3166 | TC |
EPA1411B_Temperature.csv
|
Data Set plots
Experiment Set Details
Name: Sara Li_Old test
Time format and units:
Description:
To investigate the SOA yield from DEGEE in low NOx condition.
Collaborators:
Contacts
Principal investigator:
David Cocker
E-mail: dcocker@engr.ucr.edu
Data Manager:
Chen Le
Phone: 9516603455
E-mail: cle030@ucr.edu
Reactants
Reactant | Compound type | Concentration | Concentration units |
---|---|---|---|
ISOPRENE | 250 | Parts Per Billion | |
H2O2 | 1.5 | Parts Per Million | |
NOx |
|
0.25 | Parts Per Million |
20110415_EPA 1411 Isoprene + NO + H2O2_TimeLine.csv
Timeline
Time (America/Los_Angeles) | Action |
06:00 | Targets: isoprene 250 ppb both; NO 250 ppb both; H2O2 3 ppm west 1.5 ppm east |
06:10 | Teco2 NO 125.24 ppb; NOx 124.02 ppb; CO 9.71 ppm; NO span starts; flow 2|40|off|40 |
06:15 | Changed NOx box scale to 500ppb |
06:33 | NO 26.37 ppb; NOx 114.50 ppb; GPT span starts; flow 2|40|2|40 |
06:47 | O3 #2 85.94 O3 span starts; flow 2|40|2|off |
07:33 | Starting E--W--Z sampling |
10:48 | Fill air off |
10:50 | Inject 100uL PF into both bags |
10:52 | Turn on air handler and chiller |
10:57 | Inject 172.5uL isoprene into both bags |
11:09 | Inject NO 28.5 torr (1089 cc bulb) to both bags |
11:10 | Mix W-E bag for 4 mins |
11:19 | Mix A for 4 minutes |
11:29 | Close valve 14 |
11:32 | Inject 300 uL 50% w/w H2O2 into East bag |
11:46 | Inject 400 uL 50% w/w H2O2 into West bag |
11:58 | Inject 200 uL 50% w/w H2O2 into West bag |
12:10 | All Blacklights on (6 lights out) Note: O3 off scale ~778ppb |
23:59 | All black lights off; East only lasted 6 hours; West lasted 8 hours |
Citations
Characterizations
(None)
Particle Loss Characterizations:
(None)
Vapor Loss Characterizations:
(None)
Chamber Details
Name: EPA chamber
Volume in cubic meters: 84.2
Shape: Rectangular Prism
Surface area in cubic meters: 126
Flow Mode: Batch
Flow through rate in liters per minute:
Body Material: Teflon
Body thickness: 2
Replacement date: 2017-11-07
Replacement frequency: As needed
Cleaning method:
Flushing with air
Flushing with air with UV lights on
Oxidation
Wipe with ultra-pure water if needed
o3 background: 10
nox background: 0
Particle background in micrograms per cubic meter: 0
Air filtration method: The chamber is using zero air from our air purification system
Mixing method: 0
Mixing method material:
Temparature Control: Yes
Temparature measurements recorded: Yes
Temparature range (min degrees celcius): 5
Temparature range (max degrees celcius): 45
Humidity Control: Yes
Humidity Measurements Recorded: Yes
Relative humidity range (min percent): 0.01
Relative humidity range (max percent): 80
Particle experiment capability: 1
Lights: Yes
Light source type(s):
350nm UVA Black Lamps
Supplemental information:
Additional Notes: